パッチ名: PHSS_36167
パッチ摘要: 11.31 rp3410/rp3440 PDC46.34/BMC03.52/MPE.03.30 FW
作成日: 07/03/26
公開日: 07/04/25
ハードウェアプラットフォームおよびOSリリース:
11.31
現象:
PHSS_36167:
BMCファームウェアリビジョン03.52での新機能、修正および拡張機能:
---------------------------------------------------------------
- CPU/システムファン障害検出アルゴリズムを改善しました。
- Baseboard Management Controllerがハング状態になり、PC、PS、RSのよう
な一部のMPコマンドに対して応答しなくなることがあるという不具合を修
正しました。
問題点の説明:
PHSS_36167:
- 上記の"現象"セクションを参照。
-----------------------------------------------------------------------------
Patch Name: PHSS_36167
Patch Description: 11.31 rp3410/rp3440 PDC46.34/BMC03.52/MPE.03.30 FW
Creation Date: 07/03/26
Post Date: 07/04/25
Hardware Platforms - OS Releases:
11.31
Products: N/A
Filesets:
OS-Core.KERN-RUN,fr=B.11.31,fa=HP-UX_B.11.31_IA/PA,v=HP
Automatic Reboot?: Yes
Status: General Release
Critical: No
Category Tags:
defect_repair enhancement general_release firmware
Path Name: /hp-ux_patches/11.X/PHSS_36167
Symptoms:
PHSS_36167:
The following features, fixes and enhancements appear in
BMC firmware revision 03.52:
----------------------------------------------------------
- Improved the CPU and system fan failure detection
algorithms.
- Corrected an issue where the Baseboard Management
Controller may appear to hang and stop responding to
certain MP commands like: PC, PS, and RS.
Defect Description:
PHSS_36167:
- See Symptoms.
Enhancement:
Yes
PHSS_36167:
- See Symptoms.
SR:
0000000000
Patch Files:
OS-Core.KERN-RUN,fr=B.11.31,fa=HP-UX_B.11.31_IA/PA,v=HP:
/usr/conf/rp3440srvrflash
/usr/conf/rp3440saveFW
/usr/conf/rp3440fw.wrap
/usr/conf/rp3440bmcfw.wrap
/usr/conf/rp3440gspfw.wrap
/usr/conf/rp3440version.inf
what(1) Output:
OS-Core.KERN-RUN,fr=B.11.31,fa=HP-UX_B.11.31_IA/PA,v=HP:
/usr/conf/rp3440srvrflash:
Server Firmware Reflash Utility version 2.08 for PA-
RISC Servers
/usr/conf/rp3440saveFW:
Data Hdr A 00.01
Save Firmware Image Utility Rev 1.0 _ HP-UX Version
11.11
/usr/conf/rp3440fw.wrap:
Data Hdr A.00.01
------------------------------------------------
MW_0328_4634
Wed Aug 16 13:34:34 PDT 2006
------------------------------------------------
ShortFin CPU API Library Version 2.20
/usr/conf/rp3440bmcfw.wrap:
Data Hdr A.00.01
/usr/conf/rp3440gspfw.wrap:
Revision E.03.30 Oct 27 2006,13:43:15
/usr/conf/rp3440version.inf:
Data Hdr A.00.01
cksum(1) Output:
OS-Core.KERN-RUN,fr=B.11.31,fa=HP-UX_B.11.31_IA/PA,v=HP:
4152844703 133152 /usr/conf/rp3440srvrflash
511149503 32865 /usr/conf/rp3440saveFW
2040396060 4195584 /usr/conf/rp3440fw.wrap
3211805621 630016 /usr/conf/rp3440bmcfw.wrap
2595979842 4434829 /usr/conf/rp3440gspfw.wrap
2699424886 53 /usr/conf/rp3440version.inf
Patch Conflicts: None
Patch Dependencies: None
Hardware Dependencies:
9000/800/rp3410
9000/800/rp3440
9000/800/rp3440#1
Other Dependencies: None
Supersedes: None
Equivalent Patches:
PHSS_36165:
s700: 11.11
s800: 11.11
PHSS_36166:
s700: 11.23
s800: 11.23
Patch Package Size: 2960 KBytes
Installation Instructions:
Please review all instructions and the Hewlett-Packard
SupportLine User Guide or your Hewlett-Packard support terms
and conditions for precautions, scope of license,
restrictions, and, limitation of liability and warranties,
before installing this patch.
------------------------------------------------------------
1. Back up your system before installing a patch.
2. Login as root.
3. Copy the patch to the /tmp directory.
4. Move to the /tmp directory and unshar the patch:
cd /tmp
sh PHSS_36167
5. Run swinstall to install the patch:
swinstall -x autoreboot=true -x patch_match_target=true \
-s /tmp/PHSS_36167.depot
By default swinstall will archive the original software in
/var/adm/sw/save/PHSS_36167. If you do not wish to retain a
copy of the original software, include the patch_save_files
option in the swinstall command above:
-x patch_save_files=false
WARNING: If patch_save_files is false when a patch is installed,
the patch cannot be deinstalled. Please be careful
when using this feature.
For future reference, the contents of the PHSS_36167.text file is
available in the product readme:
swlist -l product -a readme -d @ /tmp/PHSS_36167.depot
To put this patch on a magnetic tape and install from the
tape drive, use the command:
dd if=/tmp/PHSS_36167.depot of=/dev/rmt/0m bs=2k
Special Installation Instructions:
1. This patch will only install and update the firmware
on these systems:
9000/800/rp3410
9000/800/rp3440
9000/800/rp3440#1
If you wish to install the patch on a different system even
though it does not apply, you can force the installation of
the patch by touching the file '/tmp/force_patch_install'
before installing the patch. This may be useful when
creating a 'golden' archive image for Ignite-UX that may be
used on several different hardware platforms.
If the patch is installed on a system other than those
listed above, it will not modify the system firmware so no
harm will occur.
2. If this patch is uninstalled it will not uninstall/
downgrade the firmware installed by the patch and the
firmware installed by the patch will remain loaded after
the patch is removed.
3. The firmware update is accomplished by temporarily
modifying the autoboot file on the primary boot disk.
To identify the disk, patch assumes that the primary boot
disk is the first disk listed in the /stand/bootconf file.
To ensure the firmware update is successful, please use the
setboot(1M) and ioscan(1M) commands to verify that the
primary boot disk is the first disk listed in the
/stand/bootconf file. If it is not, modify the bootconf
file appropriately. Please reference the man page for
bootconf(4) for information on this file.
4. It is recommended that the firmware update is performed
outside of an OS install or Update-UX session. If a firmware
update is performed, it will be excluded from installation
to ensure that OS install or Update UX is successful.
5. The firmware update will be excluded from installation
if the firmware revision in the patch is the same and older
than the one the system is running on. This will ensure
that no un-necessary system reboot occurs.
6. Any future firmware versions in the system can be
downgraded with firmware in this patch by touching the file
'/tmp/force_patch_install' before installing the patch as
well as removing any superseding patches.
7. The firmware update will be excluded from installation
if the system is running in a VPAR session. To update the
firmware, shut down all VPAR's and reboot the server into
standalone mode using the primary path.
8. The firmware update will be excluded from installation
if the autoboot flag is not set. This is to ensure that the
end-to-end firmware update process goes smoothly without
user intervention once the patch installation is started.
Please use setboot(1M) command to set the autoboot flag
on prior to installing the patch.
9. The firmware update will be excluded from installation
if the BMC Administrator Password is set. To update the
firmware, clear the password by interacting with the
MP's Command Menu and use the 'BP' command.
10. The firmware update will be aborted if the currently
installed MP firmware revision is less than E.02.29. In
order to upgrade firmware using this patch first
update the MP firmware to E.02.29 and then install this
patch.
11. If the currently installed MP firmware revision is
E.03.13 or later, the MP firmware update will fail
if the "Allow MP Firmware upgrade via PCI" option is
Disabled in the MP Security Options menu. To update
the firmware using this patch, enable this option in
the MP Security Options Menu.
12. Prior to updating the iLO MP firmware a MP reset
needs to occur via the "XD-R" command in order to free
up enough contiguous memory.
|